Removing the DC Power Supply Module

Copyright © 2018, Juniper Networks, Inc.
To remove the DC power supply module from a Junos Space Appliance, do the following:
Switch off the dedicated facility circuit breaker for the power supply module being
1.
removed.
(Optional) Attach an electrostatic discharge (ESD) grounding strap to your bare wrist,
2.
and connect the strap to an external ESD point.
Make sure that the voltage across the DC power source cable leads is 0 V and that
3.
there is no chance that the cables might become active during the removal process.
Remove the clear plastic cover protecting the terminal studs on the faceplate.
4.
Remove the screws from the terminals, using a Phillips screwdriver, number 2 to loosen
5.
and remove the screws. Save the screws.
Remove the cable lugs from the terminals.
6.
Remove the screw on the grounding terminal by using the screwdriver. Save the screw.
7.
Remove the grounding lug from the grounding terminal.
8.
Carefully move the power cables out of the way.
9.
Slide the ejector lever to the right, as shown in
10.
furthest position.

Figure 18: Removing a DC Power Supply Module

1— Power supply ejector lever
Chapter 15: Replacing Components
Figure 18 on page
159, until it is in its
159