Figure 11: Connecting A Dc Power Supply Module - Juniper JA2500 Hardware Manual

Junos space appliance hardware guide
Hide thumbs Also See for JA2500:
Table of Contents

Advertisement

Juniper Networks JA2500 Junos Space Appliance Hardware Guide
86
circuit breaker on the panel board that services the DC circuit, switch the
circuit breaker to the OFF position, and tape the switch handle of the circuit
breaker in the OFF position.
To connect the DC source power to the Junos Space Appliance, do the following:
(Optional) Attach an electrostatic discharge (ESD) grounding strap to your bare wrist
1.
and connect the strap to an external ESD point.
Ensure that the power supply module is fully inserted in the chassis.
2.
Ensure that the input circuit breaker is open so that the voltage across the DC power
3.
source cable leads is 0 V and that the cable leads will not become active when you
connect the DC power.
Remove the clear plastic cover protecting the terminal on the faceplate.
4.
Remove the screws on the terminals by using the screwdriver. Save the screws.
5.
Connect the stripped and twisted wires to wire clamps under the DC terminal screws
6.
as shown in
Figure 11 on page

Figure 11: Connecting a DC Power Supply Module

Use the terminal screws to secure the power source cables to the power feed on the
7.
appliance by attaching the twisted wires that are attached to the cables to the
appropriate terminals.
Remove the screw on the grounding terminal by using the screwdriver. Save the screw.
8.
The grounding terminal is located to the right and above the terminals, as shown in
Figure 12 on page
87.
86.
Copyright © 2018, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos space ja1500

Table of Contents