Installing the AC Power Supply Module

Copyright © 2018, Juniper Networks, Inc.

Figure 16: Removing the AC Power Supply Module

1— Power supply ejector lever
Grasp the power supply handle and pull firmly to slide the power supply module
7.
halfway out of the appliance.
Place one hand under the power supply module to support it and slide it completely
8.
out of the appliance. Take care not to touch power supply components, pins, leads,
or solder connections.
Place the power supply module in the antistatic bag or on the antistatic mat on a flat,
9.
stable surface.
To install the AC power supply module, do the following:
Remove the replacement power supply module from its antistatic bag, taking care
1.
not to touch power supply pins, leads, or solder connections.
(Optional) Attach an electrostatic discharge (ESD) grounding strap to your bare wrist,
2.
and connect the strap to an external ESD point.
If the power supply slot has a cover panel on it, slide the ejector lever (on the cover
3.
panel) to the right and then take out the cover. Save the cover panel for later use.
Insert and push the new power supply module into the slot, as shown in
4.
Figure 17 on page
156, until the ejector lever locks.
Chapter 15: Replacing Components
155