The appliance must be installed in a rack housed in a dry, clean, well-ventilated, and
temperature-controlled environment.
Ensure that the following environmental guidelines are followed:
Keep the site as dust-free as possible because dust can clog air intake vents and filters,
reducing the efficiency of the appliance cooling system.
Maintain ambient airflow for normal appliance operation. If the airflow is blocked or
restricted, or if the intake air is too warm, the appliance might overheat.
Table 11 on page 19
provides the required environmental conditions for normal appliance
operation and
Table 12 on page 19
appliance (nonoperational).

Table 11: Environmental Specifications for Appliance Operation

Description
Altitude
Relative humidity
Temperature

Table 12: Environmental Specifications for Appliance Storage

Description
Altitude
Relative humidity
Temperature
General Safety Guidelines and Warnings on page 37
General Site Guidelines for Junos Space Appliances on page 17
the environmental specifications for storing the
Tolerance
No performance degradation upto 10,000 ft (3048 m)
Normal operation ensured in the relative humidity range of 8% to
90%, noncondensing
Normal operation ensured in the temperature range of 41° F to
104° F (5° C to 40° C)
Tolerance
The appliance can be stored safely upto 40,000 ft (12,192 m)
The appliance can be stored safely in the relative humidity range
of 5% to 95%, noncondensing
The appliance can be stored safely in the temperature range of
–40° F to 158° F (-40° C to 70° C)