Initial System Administration
The system displays the Machine Profile screen
2. Move the cursor to the Machine Name field and type the new name to be
assigned to this DEFINITY AUDIX system. The machine name must be
from 1 to 8 characters in length.
3. Verify that the Machine Type field displays audix. If not, move the cursor
to that field and type audix.
4. Move the cursor to the Extension Length field and type the number of
digits that the extensions on this DEFINITY AUDIX system will have.
5. Move the cursor to the ADDRESS RANGES fields, and fill in the starting
and ending switch extensions that will have coverage on this DEFINITY
AUDIX system.
6. For the remaining fields, change only the fields whose values on the
worksheet are different from the default.
7. Press the
8. Proceed to Task 14C: Run the Switch Translations Audit.

Task 14C: Run the Switch Translations Audit

This task is required for all installation scenarios.
The switch translations audit examines and updates internal data used by the
switch interface.
3-14
Issue 2 December 1996
(F3) function key to save the changes.