12. Attach the other end of the short ribbon cable to the top connector on the component side of
the circuit pack (red line on the bottom). See
page 67.
13. Push the tabs on the ends of the connector inward to lock the connector in place.
14. Thread the ribbon through the slot on the front panel.
15. Fully insert the TN2312BP Internet Protocol Server Interface (IPSI-2) circuit pack only.
16. Assign the Switch and Cabinet ID to the TN2312BP Internet Protocol Server Interface
(IPSI-2) just inserted. See
17. Type set tone cabinet carrier and press Enter to force a tone-clock interchange.
18. Type status port-network number where number is the number of the port network
and press Enter to verify that the tone-clock moved to the other carrier. Verify that the
YELLOW LED on the IPSI circuit pack is flashing.
19. Remove the TN2182 Tone Clock circuit pack from the new standby carrier (B) and place in
an antistatic carrier.
20. Insert the TN2312BP Internet Protocol Server Interface (IPSI-2) circuit pack part way into
the TONE-CLOCK slot on the standby carrier (B).
21. With the red line on the bottom (pin 1), attach one end of the long ribbon cable to the
connector on the component side of the circuit pack.
22. Push the tabs on the ends of the connector inward to lock the connector in place. See
Ribbon Cable Connector
23. Thread the ribbon through the slot on the front panel.
24. Attach the other end of the long ribbon cable to the bottom connector on the component
side of the TN775D Maintenance (EPN) circuit pack (red line on the bottom). See
Critical Reliability Ribbon Cable Connection
25. Fully insert the TN2312BP Internet Protocol Server Interface (IPSI-2) circuit pack.
26. Program the TN2312BP Internet Protocol Server Interface (IPSI-2) just inserted. See
Assigning IP addresses to the IPSI circuit packs
27. Fully insert the TN775D Maintenance (EPN) circuit pack after both IPSIs have been
programmed.
Upgrading and administering the existing hardware
Duplex Reliability Ribbon Cable Connection
Assigning IP addresses to the IPSI circuit packs
on page 66.
on page 70.
on page 122.
Issue 4 January 2005