1. Type list cabinet and press Enter to determine which PNs have TN2182 Tone Clock
circuit packs and in which cabinets they are in.
2. In cabinets receiving an IPSI circuit pack, remove the TN2182 Tone Clock circuit pack from
the expansion control carrier and place it in an antistatic carrier.
Note:
If present, do not remove the TN771 Maintenance/Test circuit pack.
Note:
3. Remove the TN775B/C Maintenance (EPN) circuit pack from the expansion control carrier
and place it in an antistatic carrier.
4. Insert the TN2312BP Internet Protocol Server Interface (IPSI-2) circuit pack part way into
the TONE-CLOCK slot.
5. With the red line on the bottom (pin 1), attach one end of the short ribbon cable to the
connector on the component side of the TN 2312AP circuit pack. See
Connector
Figure 4: Ribbon Cable Connector
6. Push the tabs on the ends of the connector inward to lock the connector in place.
7. Thread the ribbon through the slot on the front panel. See
Connection
or S8710 Multi-Connect configuration because of the two media servers.)
8. Insert the TN775D maintenance circuit pack part way into the MAINTENANCE slot.
9. Attach the other end of the short ribbon cable to the top connector on the component side of
the TN775D circuit pack (red line on the bottom). See
Connection
66 Migrating to the Avaya S8700 Media Server
on page 66.
on page 67. (Standard reliability is referred to as duplex reliability in the S8700
on page 67.
caxxinst LJK 022002
Duplex Reliability Ribbon Cable
Duplex Reliability Ribbon Cable
Ribbon Cable