Output Format (Non-Procedure) - Omron FZ3 Series User Manual

Vision sensor
Table of Contents

Advertisement

<Response>

Output Format (Non-procedure)

If the processing unit [Data Output] is set in a scene, measurement results are sequentially output
starting from the smallest data No. set in [Setting] of [Data Output].
Reference:
When Outputting ASCII Data
Set the output format as "ASCII" in [Setting] of the [Data Output] processing item.
6
The factory settings default value is "ASCII".
Output format
Note
The output format, number of digits and the data separator, etc. can be changed if necessary.
Reference:
Example) Integer digits: "5 digits", decimal places: "3 digits", negative numbers: "-", field separator:
"comma", record separator: "delimiter"
Note
Field separators are not output in the absence of the following data.
The range of values that can be output is as follows:
-999999999.9999 <= Measurement value <= 999999999.9999
When measurement value is < -999999999.9999, "-999999999.9999" is output.
When measurement value is > 999999999.9999, "999999999.9999" is output.
When JG (Judgement) is set, the next value is output.
OK:1
NG:-1
Note
Even if measurement is complete, data output will not stop until all of the data is output. Please note, data
output will not be interrupted.
When outputting
176
Controlling/Outputting through Serial Communication (Non-procedure)
"Processing Item List Manual", "Data Output" (p.398)
"Processing Item List Manual", "Data Output" (p.398)
FZ3 User's Manual