Omron FZ3 Series User Manual page 150

Vision sensor
Table of Contents

Advertisement

Important
Before setting the communication specifications, set the "Serial (RS-232C/422)" communication module to
either "Normal" or "Normal (Fxxx series method)", store to the controller, then restart the system.
Reference:
Use the same communication specification settings for the controller and the external device.
Note
During setting of communication specifications, input signals cannot be handled.However, the input status can
be checked with [Confirmation].
Reference:
When data is output via serial communication, output is suspended while communication specifications are
being set.
1.
On the Main screen, tap the [System] menu - [Communication] - [Serial] - [RS-232C/422].
The Serial window is displayed.
2.
Tap [Setting] to set communication specifications.
6
Item
Interface
Baud rate
[bps]
[Note 1]
148
Controlling/Outputting through Serial Communication (Non-procedure)
Setting the Start-up Status [Startup Setting] (p.112)
Checking Communication Status (Non-procedure) (p.149)
Set value
[Factory default]
[RS-232C]
Adjust to the PC communication specifications.
RS-422
2400
4800
9600
19200
Adjust to the PC communication specifications.
[38400]
57600
115200
Description
FZ3 User's Manual

Advertisement