"Save to memory + file" setting example and save destination
Folder name: USBDisk
Prefix: image_
"Switch saving folder by scene":
Checked
"Switch saving folder by judge":
Checked
3
4.
Set the image logging priority conditions.
This setting is only valid when "Save to memory + file" is selected in the image logging saving
conditions.
When the measurement tact time is short, time lag may occur with writing from the controller
memory to the RAMDisk or USBDisk and temporary absences of free space in the controller
memory may occur.Select whether logging or measurement has priority at these times.
Setting item
Logging
priority
5.
Set the data logging conditions.
The data format is set with the processing item "Data Logging".
86
Useful Functions for Operation
Example of setting
Set value
[Factory
default]
When there is no free capacity in the controller memory, subsequent
measurement cannot be received until free capacity becomes
[Logging]
available.
All measurement target images are logged, but the measurement tact
time becomes longer.
Measurement will continue even if there is no free capacity in the
controller memory.New logging is not performed until free capacity
Measurement
becomes available in the controller memory.
The measurement tact time is maintained, but some measurement
may not be logged.
Save destination
Saving will be performed as follows for the settings example
on the left
OK image save destination:
\USBDisk\S000-000\OK\image_(Measurement ID).IFZ
NG error image save destination:
\USBDisk\S000-002\NG\image_(Measurement ID).IFZ