Omron FZ3 Series User Manual page 89

Vision sensor
Table of Contents

Advertisement

Set value
Setting item
[Factory
default]
[None]
Data
Only NG
Logging
All
6.
Set the logging data save destination.
Set value
Setting item
[Factory default]
[RAMDisk]
Folder name
USBDisk
Note
About loading data to a PC
Factory settings are set so that logging data is saved in the controller RAMDisk.
When logging data is loaded to a PC, set USBDisk as the save destination.
Logging data is first saved to the controller RAMDisk and then can be copied from the RAMDisk and
saved to the USBDisk using "Copy files" in "Save to file".
7.
Tap [OK].
Settings are confirmed and the Logging Setting window closes.
Important
Logging images saved in the controller memory are overwritten starting with the oldest image if the upper limit
for the number of save images is exceeded.
Reference:
About Number of Logging Images (p.292)
The data saved in the controller memory or RAMDisk is deleted when the controller is restarted.
FZ3 User's Manual
Measurement data is not saved.
Measurement data is saved when an NG error occurs in a unit before
"Data Logging".If an NG error occurs after the "Data Logging"
processing unit, data logging is not performed.
All measurement data is saved.
The data is saved in the specified destination folder (RAMDisk or
USBDisk).Set the file name with the processing unit [Data
Logging].
Description
Description
Useful Functions for Operation
3
87

Advertisement

Table of Contents
loading

Table of Contents