Omron FZ3 Series User Manual page 74

Vision sensor
Table of Contents

Advertisement

List of Sub Image Numbers
Classification
3
2D measurement
72
Arranging the RUN Window
Processing item
ECM Search
Edge Position
Edge Pitch
Scan Edge Position
Scan Edge Width
Gravity and Area
Labeling
Labeling+
Defect
Precise Defect
Fine Matching
Measurement Image Switching
Position Compensation
Trapezoidal Correction+
Extract Color Filter
Stripes Removal Filter+
Halation Cut+
Panorama+
Polar Transformation
Display Image File
Display Last NG Image
Sub image number and display
0: Measurement image
1: Measurement image displayed with matching edges
overlaid
0: Measurement image
1: Profile display
0: Measurement image
1: Profile display
0: Measurement image
1: Scan region
0: Measurement image
1: Scan region
0: Measurement image
1: Extracted image
0: Measurement image
1: Extracted image
0: Measurement image
1: Color extraction image
0: Measurement image
1: Defect profile [when area measurement is present]
0: Measurement image
1: Defect profile [when area measurement is present]
0: Measurement image
1: Difference image display
0: Reset image
1: Measurement image
0: After compensation
1: Before compensation
0: Post-conversion image
0: Color extraction image
1: Measurement image
0: Post-conversion image
0: Color extraction image
0: Post-combination image
0: Post-conversion image
1: Measurement image
0: Image 0
1: Image 1
2: Image 2
3: Image 3
0: Last NG
1: Previous NG error image (Displayed when there are 2
or more saved images. Otherwise, "Last NG" is
displayed.)
2: NG error image from 2 previous (Displayed when
there are 3 or more saved images. Otherwise, "Last NG"
is displayed.)
3: NG error image from 3 previous (Displayed when
there are 4 or more saved images. Otherwise, "Last NG"
is displayed.)
FZ3 User's Manual

Advertisement

Table of Contents
loading

Table of Contents