The latest NG error image resulting from an overall judgement is displayed.
The latest measurement results are always shown in overall judgement and measurement time. In
Last NG
this case, the overall judgement result and measurement time may conflict with the camera images.
Also, during continuous measurement, "Last NG" cannot be displayed.
Note
Tapping the Image Display area or flow when "Last NG" is displayed and made active clears the screen.Be sure
to capture "Last NG" before performing any other operation.
If a measurement trigger is input during multi-input status or immediately after BUSY is turned off (during
display update processing, etc.), "Last NG" cannot be displayed.
[Display Last NG Image] fulfills a similar function as a processing item in which up to 4 NG error images can be
saved.If this processing item is used, "Last NG" can be acquired without operation having any effect on
acquisition.