<Command format>
<Response format>
When processing is performed normally
When processing is not performed normally
<Parameters explanation>
Specifies the No. of the image data to be saved (0 to max. number of logging images (I_MAX)).
Image data
The maximum number of logging images can be a number with a maximum of 3 digits.The number
No.
of images will vary depending on the controller used and the camera connected.
Reference:
Specifies the save destination and file name during saving with a definite path (ex.:
\USBDisk\abc.IFZ).
Save
Save destinations include directories under the following systems.Be sure to attach an "IFZ"
destination
extension to the file name.
- RAMDisk
- USBDisk
Important
If the specified file name already exists, this existing file will be overwritten
Do not turn off power to the controller until there is a response.
(Example)
When the image data of image data No. 3 is saved with the file name "LABEL1.IFZ" in the "IMG01"
folder in the USB memory to which the drive name "USBDisk2" is assigned
<Command>
<Response>
MEASURE or M
Executing measurement
Executes measurement one time.
FZ3 User's Manual
About Number of Logging Images (p.292)
Controlling/Outputting through Serial Communication (Non-procedure)
6
159