Important
Set the image mode to "Freeze".
●
When loading images consecutively at high speed, there are restrictions on the number of images that can be
●
loaded. In the condition in which the maximum number of images that can be loaded have been loaded, the
READY signal is not turned ON until the measurement processing is complete. Therefore, the next STEP cannot
be input.
Reference:
About Max. Number of Loading Images during Multiple Image Input (p.295)
Important
Even if the image mode is "Through", the multi-input function can be used.Note, however, that the READY
●
signal is always off at this time and whether image input is complete cannot be observed from the outside. Even
if the READY signal remains off, STEP signals can be accepted without the ERROR terminal turning on.
Therefore, at this time, make the STEP signal input interval slightly longer than the input image time.
FZ3 User's Manual
Controlling/Outputting through Parallel Communication
6
191