Setting Communication Specifications (RS-232C/422 - Non-procedure)

Communication specifications such as communication speed and IP addresses are set for serial
interface (RS-232C/422 connection) communication.
Reference:
Setting Communication Specifications (Ethernet - Non-procedure) (p.145)
FZ3 User's Manual
Set value
[Factory default]
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[10.5.5.100]
0.0.0.0 to
255.255.255.255
[255.255.255.0]
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[10.5.5.110]
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[10.5.5.1]
[Normal]
[ASCII]
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[0.0.0.0]
0 to 65535
[9600]
Controlling/Outputting through Serial Communication (Non-procedure)
Description
Set the IP address of the controller.
When "Obtain an IP address
automatically" is selected, the IP
address of the controller will be
automatically obtained.
When "Use the following IP address"
is selected, set the IP address,
subnet mask, and the default
gateway address.
Input the controller IP address.
Input the subnet mask address.
Input the default gateway address.
Input the DNS server address.
This item cannot be changed.
This item cannot be changed.
Input the output destination IP
address.
Set the port No. to use for data I/O
with the controller.
6
147