Setting the Communication Specifications

Setting the Communication Specifications
Change the settings of the controller communication specifications for non-procedural
communication with the external device.
Use USB cable or RS-232C cable to connect ZS Series controllers to external devices. For USB cable
connection, install Smart Monitor ZS and USB driver beforehand. After installing Smart Monitor ZS, USB
ports are recognized as standard COM ports, and communication is achieved as with the RS-232C.
(Setting the communication specifications including baud rate is not necessary.) For details on how to
connect cable, refer to the User's Manual for each controller.
1.
Set the mode switch to "FUN".
2.
Select [System] - [Communication] - [Mode] menu.
3.
Select [non-procedural].
4.
For RS-232C cable connection, select [System] - [Communication] - [RS-232C]
menu to set the appropriate communication specifications for the external
device.
5.
Save the settings.
If you are connecting multiple controllers, set all controllers other than ZS-HLDC to [non-procedural].
Note that the communication with SmartMonitor ZS is not available in [non-procedural] mode. If you
want to communicate with SmartMonitor ZS, reset to [CompoWay/F] communication.