Avaya Communication Server 1000M Series Upgrade page 86

Meridian 1 51c sg cp piv upgrade
Table of Contents

Advertisement

Page 86 of 198
Performing the upgrade
Reconfigure I/O ports and call registers
NN43021-459
Standard 05.04
ISSP
SLT
TID
****
Procedure 16
Reconfiguring I/O ports and call registers
1
Evaluate the number of call registers and 500 telephone buffers that are
configured for the system (suggested minimum values are 20,000 and
1000 respectively). If changes are required, reconfigure the values in LD
17:
LD 17
CHG
CFN
PARM YES
500B 1000
NCR 20000
****
2
Print the Configuration Record to confirm the changes made above:
LD 22
REQ PRT
TYPE CFN
****
March 2012
Print System, DepList, and Patch information
Print System Limits
Print the Tape ID
Exit program
Load program
Use 1000 as a minimum value
Use 20000 as a minimum value
Exit program
Load program
Set the print Option
Print the configuration
Exit program
End of Procedure

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs 1000m seriesCs 1000m sgCs 1000m mg

Table of Contents