Avaya Communication Server 1000M Series Upgrade page 111

Meridian 1 51c sg cp piv upgrade
Table of Contents

Advertisement

Test Core/Net 1
Procedure 29
Testing Core/Net 1
1
Check dial-tone.
2
Test the clocks:
a.
Verify that the clock controller is assigned to the active Core.
LD 60
SSCK x
SWCK
****
b.
Verify that the clock controllers are switching correctly.
SWCK
SWCK
****
3
Stat D-channels:
LD 96
STAT DCH
****
4
Stat all T1 interfaces:
LD 60
STAT
****
Performing the upgrade
Load program
Get the status of the clock controllers (x is "0" or
"1" for Clock 0 or Clock 1)
To switch the Clock (if necessary)
Exit program
Switch the Clock
Note: You must wait a minimum of one minute for
clocks to synchronize.
Switch the Clock again
Exit program
Stat all D-channels
Exit program
Stat all DTI and PRI
Exit program
51C to CS 1000M SG CP PIV Upgrade
Page 111 of 198

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs 1000m seriesCs 1000m sgCs 1000m mg

Table of Contents