Preparing and planning for the upgrade
NN43021-459
Standard 05.04
Result: If the backup is successful, the system displays a message that
states that the database backup is complete and generates a report that
indicates which floppy drives were used.
4
If there are validation errors, repeat the procedure.
CAUTION — Service Interruption
Loss of Data
If the backup is not successful, do not continue;
contact your technical support organization. Any
backup problems must be corrected before the
system is upgraded to CP PIV.
5
Once the backup is complete, type:
****
Procedure 5
Converting the 4 Mbyte database media to 2 Mbyte database media
Database conversion for Meridian 1 Options 21E, 51,
61,71, STE, NT and XT must be completed by Avaya
Software Conversion Lab. Consult the current Avaya price
book for cost and contact information.
IIf the system is equipped with IODUC cards, the
database should be data dumped (EDD) to a blank 2 MB
floppy.
All systems can be converted by Avaya in the software
conversion lab.
Before the system is upgraded to CP PIV, you must convert the database to
2 MB media. Systems with an IODU/C drive already have 2 MB media and can
skip this procedure.
March 2012
Exit program
End of Procedure