Avaya Communication Server 1000M Series Upgrade page 156

Meridian 1 51c sg cp piv upgrade
Table of Contents

Advertisement

Page 156 of 198
NN43021-459
Standard 05.04
lnstalling a Signaling Server
Figure 36
Selected J2-J5 plate on back panel of UEM
8
Establish an ELAN port on the back panel of the UEM.
a.
Insert the end of one of the RJ-45 CAT5 Ethernet patch cables
(supplied) into the ELAN network interface (ELAN port) on the Server
faceplate.
b.
Route the Ethernet patch cable through the hole you made in the
back panel of the UEM.
c.
Plug the other end of the Ethernet patch cable into one of the
Ethernet port couplers mounted in the Ethernet port adapter plate.
d.
Label the Ethernet port coupler as ELAN.
See Figure 37 and Figure 38.
March 2012