Performing the upgrade
Table 13
Clock Controller switch settings for NTRB53 (Part 2 of 2)
Multi Group
Machine
Single group
Type #1
Note: Switches 7 and 8 are not used.
Power up Core/Net 1
NN43021-459
Standard 05.04
Faceplate Cable Length
CC to CC
Off
On
On
Procedure 12
Preparing for power up
1
Check that a terminal is connected to the J25 I/O panel connector
(COM 1) on Core/Net 1.
Note: A maintenance terminal is required to access the Core/Net
modules during the upgrade.
2
Connect a terminal to the J25 port on the I/0 panel in Core/Net 1.
3
Check the terminal settings as follows.
a.
9600 baud
b.
8 data
c.
parity none
d.
1 stop bit
e.
full duplex
March 2012
On
4.6–6.1 m
(15–20 ft.)
Off
6.4–10.1 m
(21–33 ft.)
On
10.4–15.2 m
(34–50 ft.)