Avaya Communication Server 1000M Series Upgrade page 85

Meridian 1 51c sg cp piv upgrade
Table of Contents

Advertisement

chg elnk inactive name 2
chg mask xxx.xxx.xxx.xxx
4
Enable the new Ethernet interface.
LD 137
update dbs
dis elnk
enl elnk
Check for Peripheral Software Download to Core 1
Enter LD 22 and print Target peripheral software version. The Source
peripheral software version was printed in "Print site data" on
there is a difference between the Source and Target peripheral software
version:
A forced download occurs during initialization when coming out of
parallel reload.
System initialization takes longer.
The system drops established calls on IPE.
Access LD 22 and print Target peripheral software version.
LD 22
REQ
TYPE
Performing the upgrade
Assign the "name 2" address to
the inactive Core.
Set the sub-net per local site.
This number allows external
sub-nets to connect to the
system.
Load program
Update the ELINK database
Disable the old IP interface values
Enable the new IP interface values
End of Procedure
Load program
PRT
PSWV
51C to CS 1000M SG CP PIV Upgrade
Page 85 of 198
page
30. If

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs 1000m seriesCs 1000m sgCs 1000m mg