Connecting an HP COTS server
Figure 45
HP DL320-G4 (rear view)
NN43021-459
Standard 05.04
lnstalling a Signaling Server
In geographic regions that are susceptible to electrical storms, Avaya
recommends that you plug the HP server into an AC surge suppressor.
Figure 45 shows the rear view of the HP DL320-G4 server.
Note: When you perform Procedure 41, "Connecting an HP COTS
server," on
page
Procedure 41
Connecting an HP COTS server
1
Connect the HP server to the TLAN subnet. Insert the RJ-45 CAT5 (or
better) cable into the TLAN Ethernet port on the back of the server. Insert
the other end of the cable into the TLAN subnet of the Layer 2 switch.
2
Connect the HP server to the ELAN subnet. Insert the RJ-45 CAT5 (or
better) cable into the ELAN Ethernet port on the back of the server. Insert
the other end of the cable into the ELAN subnet of the Layer 2 switch.
3
Connect a DTE–DTE null modem serial cable from the Serial Port on the
back of the server to a maintenance terminal.
4
Connect the HP server power cord.
March 2012
168, see Figure 45.