a.
Perform a visual check of the LCDs.
3
Test the System Utility cards and the cCNI cards:
LD 135
STAT SUTL
TEST SUTL
STAT CNI c s
TEST CNI c s
4
Test system redundancy:
LD 137
TEST RDUN
DATA RDUN
STAT FMD
STAT RMD
5
Install the two system monitors. Test that the system monitors are
working:
LD 37
ENL TTY x
STAT XSM
****
6
Clear the display and minor alarms on both Cores:
LD 135
CDSP
CMAJ
CMIN ALL