Connecting a Dell COTS server
Figure 46
Dell R300 server (rear view)
NN43021-459
Standard 05.04
lnstalling a Signaling Server
In geographic regions that are susceptible to electrical storms, Avaya
recommends that you plug the Dell server into an AC surge suppressor.
Figure 46 shows the rear view of the Dell R300 server.
Note: When you perform Procedure 42, "Connecting a Dell COTS
server," on
page
Procedure 42
Connecting a Dell COTS server
1
Connect the Dell server to the TLAN subnet. Insert the RJ-45 CAT5 (or
better) cable into the TLAN Ethernet port on the back of the server. Insert
the other end of the cable into the TLAN subnet of the Layer 2 switch.
2
Connect the Dell server to the ELAN subnet. Insert the RJ-45 CAT5 (or
better) cable into the ELAN Ethernet port on the back of the server. Insert
the other end of the cable into the ELAN subnet of the Layer 2 switch.
3
Connect a DTE–DTE null modem serial cable from the Serial Port on the
back of the server to a maintenance terminal.
4
Connect the Dell server power cord.
March 2012
170, see Figure 46.