Avaya Communication Server 1000M Series Upgrade page 67

Meridian 1 51c sg cp piv upgrade
Table of Contents

Advertisement

f.
XOFF
Note: If only one terminal is used for both Cores, the terminal must be
switched from side to side to access each module. An A/B switch box can
also be installed to switch the terminal from side to side.
Procedure 13
Powering up Core/Net 1
1
Faceplate-enable all Core and Network cards in Core/Net 1.
2
For AC-powered systems (NT8D29BA), set the MPDU circuit breaker
located at the left end of the module to ON (top position.)
3
Set the breaker for the Core 1 module in the back of the column pedestal
to ON (top position).
4
For DC-powered systems, faceplate-enable the NT6D41CA power supply
and then set the breaker for the Core 1 module in the back of the column
pedestal to ON (top position).
5
Check that the Network and I/O cards have working power.
6
Allow the system Load/initialize before beginning the software installation.
CS 1000 Release 7.5 upgrade
Upgrading the software
Procedure 14 outlines the steps involved in installing CS 1000 Release 7.5
for the CP PIV processor.
Procedure 14
Upgrading the software
1
Check that a terminal is now connected to COM 1port in CP 1. The
settings for the terminal are:
a.
Terminal type: VT100
b.
9600 Baud
Performing the upgrade
End of Procedure
End of Procedure
51C to CS 1000M SG CP PIV Upgrade
Page 67 of 198

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs 1000m seriesCs 1000m sgCs 1000m mg

Table of Contents