Avaya Communication Server 1000M Series Upgrade page 149

Meridian 1 51c sg cp piv upgrade
Table of Contents

Advertisement

instructions, see Avaya Linux Platform Base and Applications Installation
and Commissioning (NN43001-315).
There are several switches on CP PM circuit cards. All switch settings
must be factory defaults except for the switch labelled S5. Switch S5
must be in position 2 to support the internal hard drive used on the
CP PM Signaling Server circuit card.
Installation in a Communication Server 1000M system
For CP PM cards, the first task that you must perform is to install the hard
drive shipped with the server or Linux upgrade kit. For instructions, see
Avaya Linux Platform Base and Applications Installation and
Commissioning (NN43001-315).
The NTDW66 CP PM card and NTDW54 CP DC card are double wide
faceplate cards designed for use in a CS 1000M Universal Equipment Module
(UEM). You can insert the double wide CP PM or CP DC card into any slot
of a CS 1000M UEM except slot 7. When upgrading from a CS 1000M
system to CS 1000E, the slot next to slot 7 is occupied by the External
Peripheral Equipment Controller (XPEC). This prevents the CP PM or CP
DC double wide faceplate from seating into slot 7.
The next task that you must perform is to install ELAN and TLAN Ethernet
ports on the back of the Communication Server 1000M UEM. These ports are
used to connect your Server to the ELAN and TLAN Ethernet subnets of your
Communication Server 1000M system.
lnstalling a Signaling Server
IMPORTANT!
51C to CS 1000M SG CP PIV Upgrade
Page 149 of 198

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs 1000m seriesCs 1000m sgCs 1000m mg

Table of Contents