c.
Data bits: 8
d.
Parity: none
e.
Stop bits: 1
f.
Flow control: none
2
Insert the RMD into the CF card slot on Call Processor 1 (inactive).
3
Perform a KDIF in LD 143.
4
Press the manual RESET button the Call Processor 1 (inactive) card
faceplate.
5
Call up the Software Installation Program during a SYSLOAD. During
SYSLOAD, the following prompt appears:
Read boot parameters from:
F: Faceplate compact flash
H: Hard Drive
0 [H]
Press F to boot from the compact flash (which contains the software).
For the CP PIV upgrade, the F must be in uppercase.