To configure a one-card module
•
When shipped, each module is configured as a master in a one-card
module. The cables on each module should be connected as shown in the
figure.
•
To configure a multi-card module into one-card modules, remove the
cables connecting the cards. then connect the free end of the 2x10 cable
to the connector labeled "Master Output" (J8) on each card (see figure
below).
If you pull on the flexible ribbon part of the 2x10 cable, you might damage
C A U T I O N
the cable assembly. Using your thumb and finger, grasp the ends of the
cable connector. Apply pressure to the ends of the cable connector to
disengage the metal locking tabs of the connector from the cable socket on
the board. Then pull the connector from the cable socket.
Installation
To configure a one-card module
5–5