Command/Query
SELect
The SELect command selects which module or intermodule will have parser
control. SELect 0 selects the intermodule, SELect 1 through 10 selects
modules A through J respectively. Parameters -1 and -2 select software
options 1 and 2. The SELect query returns the currently selected module.
Command
STARt
The STARt command starts the specified module or intermodule. If the
specified module is configured for intermodule, STARt will start all modules
configured for intermodule.
Command
STOP
The STOP command stops the specified module or intermodule. If the
specified module is configured for intermodule, STOP will stop all modules
configured for intermodule.
Query
SYSTem:ERRor?
The SYSTem:ERRor query returns the oldest error in the error queue. In
order to return all the errors in the error queue, a simple FOR/NEXT loop can
be written to query the queue until all errors are returned. Once all errors
are returned, the queue will return zero.
Command/Query
SYSTem:PRINt
The SYSTem:PRINt command initiates a print of the screen or listing buffer
over the current printer communication interface. The SYSTem:PRINt query
sends the screen or listing buffer data over the current controller
communication interface.
Programming the Agilent 16522A
Mainframe Commands
3–7