Agilent Technologies 16522A Reference
The Sequence Menu
Merge is not allowed in the following cases:
Within a repeat loop.
Within an IF block (starting with the vector prior to the if and ending with
the vector following the IF).
Between the start and first vector of the main sequence.
After the last vector of the main sequence.
Between the init and main sequence.
Between the start and first vector of the init sequence.
Within an empty init sequence (insert one vector in the init and merge
after that vector).
Copy
Selecting the Copy field brings up a pop-up menu that lets you select vector
sequence lines to be copied and a location to insert them after. The values in
the Start, End, and Copy After fields can be selected with the knob or with
the pop-up keypad that appears when the appropriate field is touched twice.
Copy will not be performed if you run out of macro calls (1000) or repeats
(1000). Copy will not be allowed if the result of the copy places an
instruction on one of the following vectors:
The first vector of the INIT sequence.
The first vector of the MAIN sequence.
The last vector of the MAIN sequence.
The vector prior to the IF block.
The first vector of the IF block.
The last vector of the IF block.
The vector following the IF block.
Insert
Touching the Insert field adds another instruction line immediately below the
line that is currently selected.