Requirements - Avaya CallPilot 1005r Maintenance And Diagnostics

Hide thumbs Also See for CallPilot 1005r:
Table of Contents

Advertisement

Replacing or adding voice processing boards
Important:
The NTRH40CA MPB96 board only connects to NTRB18DA or later MGate cards.
Caution:
Risk of electrical damage
• Wear an antistatic ESD wrist strap when handling cards or boards, or when working
inside the server.
• Do not touch the components or gold-edge connectors of cards or boards.
• Place the board on an antistatic surface until you are ready to install it.
MPB96 boards are not hot-swappable and you must power down the system before adding
boards.

Requirements

• Phillips (cross head) screwdriver, #1 and #2 bit
• High capacity upgrade kit (two or three MPB96 boards, and a CT bus cable)
Important:
DS30 cables are not supplied with the upgrade kit. The NTRH40CA uses standard CAT5e
(or greater) Ethernet-type cables. For a detailed description of these cables see CS 1000
and CallPilot Server Configuration guide (NN44200-312).
Note:
To add MPB96 boards
1. Courtesy stop all CallPilot channels. Refer to
2. Power down the server, unplug all peripheral devices and ethernet cables, and
3. Attach the ESD strap to your wrist and attach the other end to a known grounded
4. Remove the chassis cover. Refer to
5. Disconnect the red power cable from the PCI riser assembly.
6. Disconnect the DS30X cable from the MPB96 board in the full-size side of the PCI
114
Avaya CallPilot® 1005r Server Maintenance and Diagnostics
page 51.
disconnect the AC power.
connection.
page 70 for instructions.
riser. Mark the cable as number 1.
If the MPB96 board is an NTRH40CA, disconnect the three DS30 cables from the
RJ-45 faceplate connectors. Mark the cables as 1, 2, and 3. The RJ-45 connectors
Starting and stopping components
Removing and replacing the server cover
on
on
December 2010

Advertisement

Table of Contents
loading

Table of Contents