Fujitsu PRIMERGY TX1330 M4 Upgrade And Maintenance Manual page 458

Hide thumbs Also See for PRIMERGY TX1330 M4:
Table of Contents

Advertisement

Appendix A
The LEDs have the following meaning:
Indicator
Status
A -
blue on
Identification
blue
flashing
B - CSS
off
(Customer
orange on
Self Service)
orange
flashing
C - GEL
off
(Global Error
orange on
LED)
orange
flashing
F - Controller off
orange on Controller failure (PCI card installed on riser card)
G - Memory
off
orange on memory module failure
H - iRMC
off
green
flashing
I - Fans
off
orange on system fan failure
K - Standby
orange on All standby voltages ok
Power
O - M.2 SSD
orange on M.2 SSD faulty
458
Description
The server has been highlighted using ServerView
Operations Manager, iRMC web interface or the ID
button on the front panel for easy identification.
The server has been highlighted for easy
identification using the iRMC (AVR) with disabled
local VGA output.
No critical event detected (CSS component).
Prefailure event detected (CSS component).
CSS component failure detected.
No critical event detected (non CSS component).
Prefailure event detected (non CSS component).
Non CSS component failure detected.
Possible causes:
– System is out of the specified temperature
range
– Defective sensor
– CPU error
– Error detected by server management
software
Controller okay
memory module running
iRMC S5 inactive
iRMC S5 okay
system fan running
Upgrade and Maintenance Manual
TX1330 M4

Advertisement

Table of Contents
loading

Table of Contents