6.3.3

Replacing hot-plug PSUs

Customer Replaceable Unit
(CRU)
Tools: tool-less
V
CAUTION!
When replacing a hot-plug PSU in a non-redundant PSU
configuration, the server must be switched off first.
Ensure to replace a defective hot-plug PSU by a new module of the
same type.
Note for servers using CMA (Cable Management Arm)
Regarding of replacing PSUs, additional tasks are needed, due to an
interference between CMA stopper and the PSUs.
Ê Push the lock spring inward to unlock the CMA stopper (see figure 70).
V
CAUTION!
In case of not enough space at the under side, unlock the CMA
stopper of the server below and pull out the CMA to the rear side.
Ê Remove the CMA stopper with the mounted crossbar (see figure 71).
Ê Hold the CMA stopper, the crossbar and the CMA including cables in the one
hand.
Ê Remove the PSU (see figure 72) and install the new PSU carefully.
Ê Mount the complete assembly (CMA stopper, the crossbar and the CMA)
again into the rail.
TX1330 M4
Upgrade and Maintenance Manual
Power supply unit (PSU)
Hardware: 5 minutes