Fujitsu PRIMERGY TX1330 M4 Upgrade And Maintenance Manual page 424

Hide thumbs Also See for PRIMERGY TX1330 M4:
Table of Contents

Advertisement

System board and components
– If applicable, M.2 SSD, see section
– If applicable, Dual microSC 64 GB Enterprise, see section
Dual microSD 64GB Enterprise" on page 410
– Memory modules:
I
Make sure that you reinstall each memory module in the slot it was
located before the replacement.
– Expansion cards:
If applicable, connect the riser card.
Ê If applicable, install the expander board, see section
expander board" on page
Ê Install the system fan module, see section
on page 83
"Reassembling" on page 67
Ê
Ê Connect all external cables.
"Connecting the power cord" on page 78
Ê
"Switching on the server" on page 80
Ê
I
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the
message CPU has been changed.
This only indicates that the CPU configuration has been altered.
There is no technical problem.
Proceed as follows:
Ê Restart your server.
Ê As soon as the startup screen appears, press the [F2] function
key to enter the BIOS.
If a password is assigned, enter the password and press [Enter].
Ê Select the Save & Exit menu.
Ê Select Save Changes and Exit or Save Changes and Reset.
Ê Verify that the Global Error indicator stops flashing.
"Verifying the system time settings" on page 113
Ê
424
"Installing a memory module" on page 314
"Installing expansion cards" on page 279
251.
Upgrade and Maintenance Manual
"Installing an M.2 SSD" on page 402
"Installing the SAS
"Installing the system fan module"
"Installing the
TX1330 M4