Parameter name
RECORDINGTONE_VOLUME
REDIRECT_TONE
REGISTERWAIT
REUSETIME
September 2017
Default value
Description
0
Specifies the volume of the call recording tone in
5dB steps.
Value Operation:
• 0: The tone volume is equal to the transmit audio
• 1: The tone volume is 45dB below the transmit
• 2: The tone volume is 40dB below the transmit
• 3: The tone volume is 35dB below the transmit
• 4: The tone volume is 30dB below the transmit
• 5: The tone volume is 25dB below the transmit
• 6: The tone volume is 20dB below the transmit
• 7: The tone volume is 15dB below the transmit
• 8: The tone volume is 10dB below the transmit
• 9: The tone volume is 5dB below the transmit
• 10: The tone volume is equal to the transmit
1
Specifies the tone to play when a call goes to
coverage.
Valid values are from 1 to 4.
900
Specifies the number of seconds between re-
registrations with the current server. Valid values
are from 30 to 86400.
60
Specifies the number of seconds that the DHCP is
attempted:
• With a VLAN ID of zero. True when L2Q is set to
• Or with untagged frames. True if L2Q is set to 0
• And before reusing the IP address and the
Installing and Administering Avaya J129 IP Phone
Comments on this document? infodev@avaya.com
level (default).
audio level.
audio level.
audio level.
audio level.
audio level.
audio level.
audio level.
audio level.
audio level.
audio level.
1.
or 2.
associated address information, that the phone
Table continues...
119