8 -

TROUBLESHOOTING###_8_###

FAULT CODE RESOLUTION

Error code index

NOTE: If you have a fault code associated with a red light flashing and an audible alarm, shut the unit down and call
your dealer for support. For a fault code associated with a yellow amber light, record the code number and use the
Aux Override button to move past this fault code. If the code appears again, contact your dealer for support.
JOYNu – Control handle error
JOYNu appears on the instrument panel. Make sure that the control handles and the auxiliary thumbwheel are in the
neutral position. If JOYNu continues to be displayed contact your dealer for support.
OPRPr – Operator presence error
OPRPr appears on the instrument panel. Make sure that you are sitting in the operator seat, the seat belt is fully
engaged, and the restraint bar (if equipped) is in the down position. If OPRPr continues to be displayed contact your
dealer for support.
CRKOn – Hydraulic enable error (EH machines only)
CRKOn appears on the instrument panel. CRKOn indicates the OPERATE button is being pressed while attempting
to start the machine. Follow the starting procedure as described in this manual. If CRKOn continues to be displayed
contact your dealer for support.
The following is a display of error codes and associated functions.
1000 to 1999 (vehicle errors)
Code
Function
1002
Engine Coolant
Temperature
1004
Hydraulic Oil Filter
Restriction
1009
Hydraulic Oil
Temperature
1014
Cluster System
Voltage
1015
Cluster System
Voltage
1025
Load Control
1030
Load Control
1041
RPM Monitoring
1045
Fuel Level
Monitoring
1201
Hydraulic Oil Filter
Restriction
1202
RPM Monitoring
1203
RPM Monitoring
1204
Start Sequence
1205
Hydraulic Enable
1206
UCM
8 - TROUBLESHOOTING
Description
High Temperature
Filter Restricted
High Temperature
Over Voltage
Under Voltage
Short Circuit
Open Circuit
Over Speed
Open Circuit
Open Circuit
Over Speed
Open / Short Circuit
Engine State Plausibility
Check
Short Circuit to Power
Configuration Time out
Code
Function
1350
Hydraulics Enable
1511
Right Brake Light
Actuation
1512
Right Brake Light
Actuation
1513
Right Brake Light
Actuation
1521
Left Brake Light Actuation Open Circuit
1522
Left Brake Light Actuation Short Circuit to
1523
Left Brake Light Actuation Short Circuit
1531
Backup Alarm Activation
1532
Backup Alarm Activation
1533
Backup Alarm Activation
1901
Power Supply
1903
Power Supply
1904
Power Supply
1905
Power Supply
1906
Power Supply
8-1
Description
Switch Implausible
State
Open Circuit
Short Circuit
Short Circuit to
Ground
Ground
Open Circuit
Short Circuit to
Ground
Short Circuit
Supply Voltage
High
Low Voltage
Input Voltage Out
of Range
Supply Voltage Out
of Range
Supply Voltage Out
of Range