2.4 Outline of Analog Signal Output Circuit

The analog signal circuit can be used only with the FCUA-DX120/DX121/DX140/DX141 unit.
Output circuit
Output conditions

2.5 Outline of Analog Signal Input Circuit

The analog signal input circuit can be used only for the FCUA-DX140/DX141.
Input circuit
Input conditions
2. SYSTEM CONFIGURATION
2.4 Outline of Analog Signal Output Circuit
R
220Ω
A0
A0*
Output voltage
Resolution
Load conditions
Output impedance
150Ω
AI
AI*
Max. input rating
Resolution
Precision
AD input sampling time 14.2ms (AI0)/42.6ms (AI1 to 3)
R
DAC
0V to ±10V (±5%)
12 bit (±10V x n/4096) (Note)
10k Ω load resistance (standard)
220 Ω
(Note) n = (2
ADC
± 15V
10V/2000 (5mV)
Within ± 25mV