Mitsubishi Electric MELDAS C6 Interface Manual page 334

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

During CC-Link communication
(Input to PLC)
Signal
Slot 1 Slot 2 Slot 3
X200
X280
X300 Unit error
X201
X281
X301 Data link state at host station
X202
X282
X302 Parameter setting status
Data link status at other
X203
X283
X303
station
Unit reset acceptance
X204
X284
X304
completed
X205
X285
X305 (Prohibited to use)
Data link startup normal
X206
X286
X306
completion
Data link startup error
X207
X287
X307
completion
Data link startup by EEPROM
X208
X288
X308
parameter normal completion
Data link startup by EEPROM
X209
X289
X309
parameter error completion
Parameter registration to
X20A X28A X30A
EEPROM normal completion
Parameter registration to
X20B X28B X30B
EEPROM error completion
X20C X28C X30C
(Prohibited to use)
X20D X28D X30D
X20E X28E X30E
X20F
X28F X30F Unit ready
Signal
Slot 1 Slot 2 Slot 3
X210
X290
X310 (Not used)
X211
X291
X311 (Not used)
X212
X292
X312 (Not used)
X213
X293
X313 (Not used)
X214
X294
X314 (Not used)
X215
X295
X315 (Not used)
X216
X296
X316 (Not used)
X217
X297
X317 (Not used)
X218
X298
X318 (Not used)
X219
X299
X319 (Not used)
X21A X29A X31A (Not used)
X21B X29B X31B (Not used)
X21C X29C X31C (Not used)
X21D X29D X31D (Not used)
X21E X29E X31E (Not used)
X21F
X29F X31F (Not used)
6. EXPLANATION OF INTERFACE SIGNALS
6.6 Signals Related to Communication
Name
Name
6-6-7
(Output from PLC)
Signal
Slot 1 Slot 2 Slot 3
Y200
Y280
Y300 Refresh command
Y201
Y281
Y301
Y202
Y282
Y302
(Prohibited to use)
Y203
Y283
Y303
Y204
Y284
Y304 Unit reset request
Y205
Y285
Y305 (Prohibited to use)
Y206
Y286
Y306 Data link start request
Y207
Y287
Y307 (Prohibited to use)
Data link startup request from
Y208
Y288
Y308
EEPROM parameter
Y209
Y289
Y309 (Prohibited to use)
Parameter registration
Y20A
Y28A
Y30A
request to EEPROM
Y20B
Y28B
Y30B
Y20C
Y28C
Y30C
(Prohibited to use)
Y20D
Y28D
Y30D
Y20E
Y28E
Y30E
Y20F
Y28F
Y30F
Signal
Slot 1 Slot 2 Slot 3
Y210
Y290
Y310 (Not used)
Y211
Y291
Y311 (Not used)
Y212
Y292
Y312 (Not used)
Y213
Y293
Y313 (Not used)
Y214
Y294
Y314 (Not used)
Y215
Y295
Y315 (Not used)
Y216
Y296
Y316 (Not used)
Y217
Y297
Y317 (Not used)
Y218
Y298
Y318 (Not used)
Y219
Y299
Y319 (Not used)
Y21A
Y29A
Y31A (Not used)
Y21B
Y29B
Y31B (Not used)
Y21C
Y29C
Y31C (Not used)
Y21D
Y29D
Y31D (Not used)
Y21E
Y29E
Y31E (Not used)
Y21F
Y29F
Y31F (Not used)
(For CC-Link)
Name
Name

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents