Mitsubishi Electric MELDAS C6 Interface Manual page 169

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
CNC SOFTWARE VERSION
CODE
[Function]
This indicates the version of the CNC software.
[Operation]
The version of the software for controller is set.
[S/W MODULE TREE]
MP
BND – 377W000 – A0
OFFM
The file registers R32 to 35 are set to the following data.
(Example) BND-377W000-A 0
(1) Mode function No. R35
(2) Serial No.
(3) Version
(Note 1) If the version is a 2-digit No., bits F~8 of R32 are set to "00H".
(Note 2) Bits 7~0 on the R32 are always "FFH".
B con-
Signal name
tact
BATTERY DROP CAUSE
[Function]
This notifies a drop in the battery voltage.
[Operation]
A drop in voltage of the data storage battery located on the front door of the controller is checked
when the power is turned ON. If the voltage is below the specified voltage (approx. 2.6V), the
"Battery alarm (BATAL)" signal turns ON, and bit 0 of this data is set to "1".
(Note)
This data will not change until the battery voltage is recovered to a normal value.
[Related signal]
(1) Battery alarm (BATAL: X42F)
6. EXPLANATION OF INTERFACE SIGNALS
6.2 PLC Input Signals (Data Type: R***)
Signal
abbreviation
SV1
(1)
(2) (3)
Item
File register
R34
Bits F~8 of R33
Bits 7~0 of R33
Bits F~8 of R32
———
Bits 7~0 of R32
Signal
abbreviation
1st system
R32~5
ALARM/DIAGN
BND-
Type
Binary
Binary
ASCII code
ASCII code
ASCII code
Always FFH
1st system
R40
6-2-9
2nd system
3rd system
8.1/2
Example
377=179AH
000=0000H
A=41H
0=30H
Blank=00H
2nd system
3rd system