Mitsubishi Electric MELDAS C6 Interface Manual page 309

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
NEAR-POINT DOG IGNORED
[Function]
When this signal is used, "Near-point detected" signal (remote I/O connector pin No. fixed signal)
which is used for dog type reference point return can be ignored (tripping of near switch can be
ignored).
The selection of two or more near-point dogs with conditions, or the activation of the "Near-point
detected" signal at a position not desirable due to the machine structure can seemingly be ignored.
Furthermore, the "Near-point detected" signal for an axis to which the "Near-point dog ignored"
signal is set can be used for other applications.
[Operation]
When the signal is turned ON, "Near-point detected" signal corresponding to the control axis can be
ignored.
The interface is shown below:
File register (R)
F E D C B A 9
B con-
Signal name
tact
TOOL GROUP NUMBER
DESIGNATION
[Function]
The group number is designated when the usage data of the group of which the tool life has been
exceeded with tool life management II is to be cleared, or when the tool being used is to be forcibly
changed.
[Operation]
The group designation range is as follows.
For group designation: 1 ~ 9999 of group number
For all groups
[Related signal]
(1) Tool change reset (TRST)
6. EXPLANATION OF INTERFACE SIGNALS
6.4 PLC Output Signals (Data Type: R***)
Signal
abbreviation
8
7
Signal
abbreviation
: 65535 (all 1)
6-4-19
1st system
2nd system
R921
R1021
6
5
4
3
2
1
0
1st system
2nd system
R930
R1030
3rd system
R1121
Bit
1st near point ignored
2nd near point ignored
:
14th near point ignored
3rd system
R1130