B con-
Signal name
tact
*
STOP
[Function]
This signal stops an ongoing axis component halfway in manual random feed mode.
The function of this signal is equivalent to those of the "Manual interlock +nth axis (*+MITn) and
–nth axis (*-MITn)" signals.
[Operation]
Turning the stop signal (*CXS7) OFF (0) causes the following:
(1) Motion of axis in manual random feed mode is decelerated and stopped.
(2) The axis component which is going to move in manual random feed mode remains stopped.
When the STOP (*CXS7) signal is turned ON (1) while an axis component is in the stop state, it
immediately resumes the operation.
(Note 1) In C6/C64, when the power is turned ON, the STOP (*CXS7) signal is automatically set to
"1". If the stop signal is not to be used, there is no need to make a sequence program for
it.
[Related signal]
For related signal, see the "Manual random feed mode (PTP)".
6. EXPLANATION OF INTERFACE SIGNALS
6.3 PLC Output Signals (Bit Type: Y***)
Signal
abbreviation
*CXS7
6-3-78
1st system
2nd system
Y7AE
Y88E
3rd system
Y96E