B con-
Signal name
tact
MANUAL NUMERICAL
COMMAND
[Function]
This signal informs that M, S, T or B (2nd miscellaneous function) command is given on the setting
and display unit.
With the signal, user PLC discriminates the command from that given in normal automatic
operation.
[Operation]
The signal turns ON when M, S, T or B signal is specified on the setting and display unit in manual
or automatic operation (other than auto start). Like "M function strobe" signal, the signal turns OFF
when "M function finish 1 or 2" signal turns ON, or in case of reset.
Example)
M03 manual numerical command
Manual numerical command (MMS)
M function strobe 1 (MF1)
M function finish 1
[Related signals]
(1) M function strobe (MFn: X644~)
(2) S function strobe (SFn: X658~)
(3) T function strobe (TFn: X650~)
(4) 2nd M function strobe (BFn: X654~)
(5) M function finish 1 (Fin 1: Y71E)
(6) M function finish 2 (Fin 2: Y71F)
6. EXPLANATION OF INTERFACE SIGNALS
6.1 PLC Input Signals (Bit Type: X***)
Signal
abbreviation
MMS
6-1-50
1st system
2nd system
X649
X6C9
3rd system
X749

Advertisement