Mitsubishi Electric MELDAS C6 Interface Manual page 176

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
SPINDLE SYNCHRONOUS
CONTROL
PHASE OFFSET DATA
[Function]
With the spindle phase shift amount calculation function, the phase error of the basic spindle and
synchronous spindle is obtained and memorized by turning the PLC signal ON at executing the
spindle synchronization. The synchronous spindle can be rotated with the handle during the spindle
phase shift calculation, so the relation between spindles can be adjusted by seeing.
If the "Spindle phase synchronous control" (SPPHS) signal is input while the "Phase offset request"
signal (SSPHF) is ON, the phase error will be aligned based on the position shifted by the
memorized phase shift amount.
Such operation makes the phase alignment easy when clamping an irregular material over.
[Operation]
The phase error memorized by the phase shift calculation is output.
Unit: 360 ° /4096
(Note 1) This data is output only during the spindle synchronous control.
[Related signals]
Spindle phase synchronous control (SPPHS: Y433)
Phase shift calculation request (SSPHM: Y435)
Phase offset request (SSPHF: Y436)
Spindle synchronous control phase error output (R55)
6. EXPLANATION OF INTERFACE SIGNALS
6.2 PLC Input Signals (Data Type: R***)
Signal
abbreviation
6-2-16
1st system
2nd system
R59
3rd system

Advertisement