Mitsubishi Electric MELDAS C6 Interface Manual page 104

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
NEAR 1ST REFERENCE
POINT nTH AXIS
[Function]
This signal indicates that the control axis is near the 1st reference point in the absolute position
detection system.
[Operation]
This signal turns ON when the control axis is in the range of the parameter set using the 1st
reference point as a base point, and turns OFF when the range is exceeded. The parameter is set
with #2057 (nrefp) and #2058 (nrefn) in the [ABS. POSI PARAM] screen.
+ direction
Near 1st reference
point (NRFn)
(Note 1) "Near 1st reference point" signal is output even while the axis is moving, but there may be
a slight deviation with the actual machine position.
Rapid traverse : Approx. 19mm at 20m/min.
Cutting feed
Note that this signal may not be output when the setting value is too small.
(Note 2) This signal is valid only with the absolute position detection system.
(Note 3) When 0 is set for #2057 (nrefp) and #2058 (nrefn) in the [ABS. POSI PARAM] screen, it
will be same as when the grid width is set.
6. EXPLANATION OF INTERFACE SIGNALS
6.1 PLC Input Signals (Bit Type: X***)
Signal
abbreviation
NRFn
1st reference point
#2057 setting value
: Approx. 9.5mm at 10m/min.
6-1-15
1st axis
2nd axis
X448
X468
#2058 setting value
3rd axis
X488
- direction

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents