Mitsubishi Electric MELDAS C6 Interface Manual page 192

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
THERMAL DISPLACEMENT
COMPENSATION AMOUNT
[Function]
During ball screw thermal expansion compensation, the compensation amount calculated based on
the "thermal expansion offset compensation amount" (R2302) and "thermal expansion max.
compensation amount" (R2303) is set in this register by the NC.
[Operation]
The "thermal expansion offset compensation amount" and the "thermal displacement max.
compensation amount" is set as a set for each axis in the R register.
The current compensation amount is set by the NC into the "thermal displacement compensate
amount" (R1600).
The thermal expansion compensation is invalid for the axis if the "thermal expansion offset
compensation amount" and "thermal expansion max. compensation amount" are set to 0.
These R registers are cleared to zero when the power is turned ON.
Thermal expansion offset
compensation amount
Unit: Minimum command unit/2
No.1 axis
No.2 axis
No.3 axis
No.4 axis
No.5 axis
No.6 axis
No.7 axis
No.8 axis
No.9 axis
No.10 axis
No.11 axis
No.12 axis
No.13 axis
No.14 axis
A unit half of the minimum command unit is the setting unit.
If the minimum command unit is 1µm and 100 is set, for example, the compensation amount will be
50µm.
6. EXPLANATION OF INTERFACE SIGNALS
6.2 PLC Input Signals (Data Type: R***)
Signal
abbreviation
Thermal expansion max.
(PLC → NC)
Unit: Minimum command unit/2
R2302
R2352
R2402
R2452
R2502
R2552
R2602
R2652
R2702
R2752
R2802
R2852
R2902
R2952
6-2-32
1st axis
R1600
compensation amount
(PLC → NC)
R2303
R2353
R2403
R2453
R2503
R2553
R2603
R2653
R2703
R2753
R2803
R2853
R2903
R2953
2nd axis
3rd axis
R1650
R1700
Thermal displacement
compensation amount
(NC → PLC)
Unit: Minimum command unit/2
R1600
R1650
R1700
R1750
R1800
R1850
R1900
R1950
R2000
R2050
R2100
R2150
R2200
R2250