B con-
Signal name
tact
REFERENCE POINT SELECT
—
METHOD
[Function]
This signal selects whether the reference point selection is common for all axes (Y730, Y731) or
independent for each axis (R2301).
[Operation]
When this signal is OFF, the reference point selection is common for all axes, and Y730 and Y731
are valid.
When this signal is ON, the reference point selection is independent for each axis, and R2301 is
valid.
[Related signals]
Reference point select 1, 2 (ZSL1, 2: Y730, Y731)
Each axis reference point select (R2301)
6. EXPLANATION OF INTERFACE SIGNALS
6.3 PLC Output Signals (Bit Type: Y***)
Signal
abbreviation
M
6-3-53
1st system
2nd system
Y737
Y817
3rd system