Mitsubishi Electric MELDAS C6 Interface Manual page 127

Cnc
Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

B con-
Signal name
tact
IN SKIP
[Function]
This signal is output while skip command (G31) is being executed.
[Operation]
The signal turns ON when:
(1) Skip command (G31) is being executed with automatic operation.
The signal turns OFF when:
(1) Block having a skip command is completed.
B con-
Signal name
tact
IN REFERENCE POINT
RETURN
[Function]
This signal is output while reference point return command is being executed.
[Operation]
The signal turns ON when:
(1) G28 command is executed.
(2) G30 command is executed.
(3) Manual reference point return mode is selected.
The signal turns OFF when:
(1) All cases other than above.
B con-
Signal name
tact
IN INCH UNIT SELECT
[Function]
This signal informs that the controller uses inch unit for data input.
[Operation]
This signal turns ON when inch unit is selected.
The inch unit mode is established when setup parameter [#1041 I_inch] is set and the power is
turned ON.
(Note 1) With G20 command (inch unit command) or G21 command (metric unit command), the
signal (INCH) does not change.
6. EXPLANATION OF INTERFACE SIGNALS
6.1 PLC Input Signals (Bit Type: X***)
Signal
abbreviation
SKIP
Signal
abbreviation
ZRNN
Signal
abbreviation
INCH
6-1-38
1st system
2nd system
X626
X6A6
1st system
2nd system
X627
X6A7
1st system
2nd system
X628
X6A8
3rd system
X726
3rd system
X727
3rd system
X728

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t