CRT CHANGEOVER
COMPLETE
[Function]
When using one setting and display unit as the display unit for multiple control units, this signal is
used to inform the control unit that it has been changed as the local display unit.
[Operation]
When this signal turns ON, the currently selected screen reappears at the rising edge of the signal.
The setting and display unit's screen is still showing the display screen for the control unit before
the changeover, so the local screen display is changed by inputting this signal.
[Time chart]
CRT changeover
CRT changeover
complete (CRTFN)
Screen display
B con-
Signal name
tact
DISPLAY CHANGEOVER
$1, $2
[Function]
The display part system of a dual part system can be changed.
[Operation]
The display part system is changed at the rising edge of each display changeover signal.
The screen display for a dual part system is a screen for displaying one of the part systems. Thus,
which part system to be displayed is determined by these signals.
If both of these signals are started up simultaneously, they will be invalid.
[Time chart]
Display part system
Display changeover
$1 mode (DISP1)
Display changeover
$2mode (DISP2)
6. EXPLANATION OF INTERFACE SIGNALS
6.3 PLC Output Signals (Bit Type: Y***)
Signal
abbreviation
CRTFN
Other controller
Screen display on other controller
Signal
abbreviation
DISPn
$1 display
6-3-4
1st system
2nd system
Y41D
Local
At least 100 ms
Or more required
Local screen display
1st system
2nd system
Y41E, 41F
$2 display
3rd system
3rd system
$1 display